Netlog III - Programmable controllers

(1 customer review)

247,20351,20 Net VAT excluded

Attention. EOL product, available while supplies last.

Netlog III is a programmable controller (PLC), engineered in a DIN 43880 enclosure, belonging to the family of controllers Netsyst and programmable in accordance with the international standard IEC61131-3.

SKU: MPS051 Category: Tags: , , , , , , , ,
3-Year Warranty
Made in italy
Ready for industry 4.0
Brand:

Netlog III is a family of programmable controllers (PLCs), engineered in a DIN 43880 enclosure, which can be programmed in accordance with the international standard IEC61131-3.

The devices are equipped with web server integrated able to make available web pages of configuration and general information on the status of the system, as well as web pages fully configurable by the user.

The basic module has 12 optoisolated logic inputs (PNP/NPN), 8 relay or static digital outputs, 4 analog inputs 16bit 0-10V/0-20mA (or 2 RTD), 2 analog outputs 0-10V. The status of the logic I/O is displayed through LEDs.

The device accepts extended range power supply from 10 to 30Vdc. The ability to operate with 12V power supply voltage simplifies the solution of various home automation applications, automotive and, in general, where a battery power supply is required.

Thanks to the use of non-volatile memory in FRAM technology (ferroelectric RAM), it has been possible to eliminate the battery, thus minimizing maintenance and environmental impact at the end of the product's life and eliminating the constraints imposed by directives for the air transport of products containing batteries.
FRAM technology also guarantees a practically unlimited number of writing cycles, thus improving the reliability of the system, and a very low power consumption even during the writing phases.

The module is available in different versions:

  • Relay Base: 2 RS232C, 12 Digital In, 4 Analog In, 8 Out Relay, 1 Ethernet.
  • Full RS485 Relay: 2 RS232C, 12 Digital In, 4 Analog In, 8 Out Relay, 1 Ethernet, 1 RS485 isolated.
  • Full RS485 Relay + Display: 2 RS232C, 12 Digital In, 4 Analog In, 8 Out Relay, 1 Ethernet, 1 RS485 isolated, Built-in Keypad/Display.

Base and Full versions are equipped with 2 RS232 serial ports and 1 Ethernet port.
The Full RS485 versions are equipped with the following drivers Fail-safe and high impedance, this allows you to connect up to 128 devices on the same network.
On the Full versions the "Display" option with 6-key keypad and 2-line alphanumeric LCD display with 16 characters is also available.

The device is expandable through the 20I/O extension modules of the Netsyst family (up to 7 addressable modules), via the I2C™ bus.

To connect the extension modules, use the appropriate corded bus extension cables (Code CBL045**00) to be ordered separately.

I/O connections are made via removable screw connectors for easier maintenance.

Netlog III was conceived with a view to safeguarding the investment in programming made by the customer both in terms of portability from/to other platforms and in terms of protection against copying and fraudulent use of the applications developed (see this link).

A wide range of libraries and function blocks (FB) is available to perform a variety of functions.
There are also some available optionally, for the use of which it is necessary to obtain the unlock code at MID (Manufacturer ID) or DID (Device ID) level. Go to the list.

The PLC is programmable in the 5 languages provided by the IEC61131-3 standard, through the development tool LogicLaba completely free programming tool.

The device is dimensionally and connectionally compatible with the previous model Netlog II.

Netlog is also available in an OEM version, for those users who want to build extremely cost-sensitive semi-custom PLCs.

Thanks to the support of the Modbus RTU/ASCII protocol, operator terminals and SCADA software can be connected.

Feature MPS051A011MPS051A001MPS051A000
DescriptionNETLOG III Full RS485 Relay with DisplayNETLOG III Full RS485 RelayNETLOG III Base Relay
Power supply10-30Vdc 4.6W10-30Vdc 4.6W10-30Vdc 3W
Powering expansions5Vdc 1.5A5Vdc 1.5A5Vdc 1.5A
Expansion busI2C (Fast mode)I2C (Fast mode)I2C (Fast mode)
Expansion modules777
ProcessorARM7@72MHzARM7@72MHzARM7@72MHz
Program Memory96 kB96 kB96 kB
Data Memory12kB RAM12kB RAM12kB RAM
Buffer memory3 kB FRAM3 kB FRAM3 kB FRAM
Mass Memory260 kB FlashEPROM260 kB FlashEPROM260 kB FlashEPROM
WatchdogYesYesYes
File systemOwnerOwnerOwner
Running time134uS/k (Logic)
406uS/k (Math)
1.37mS/k (Floating)
134uS/k (Logic)
406uS/k (Math)
1.37mS/k (Floating)
134uS/k (Logic)
406uS/k (Math)
1.37mS/k (Floating)
Memory utilization12kB/k (Logic)
18kB/k (Math)
39kB/k (Floating)
12kB/k (Logic)
18kB/k (Math)
39kB/k (Floating)
12kB/k (Logic)
18kB/k (Math)
39kB/k (Floating)
Status IndicatorsPWR, RUN, RDY, I/O StatusPWR, RUN, RDY, I/O StatusPWR, RUN, RDY, I/O Status
Digital inputs12 Opto-isolated PNP/NPN12 Opto-isolated PNP/NPN12 Opto-isolated PNP/NPN
Digital outputs8 Relays8 Relays8 Relays
Analog inputs444
A/D resolution16 Bit16 Bit16 Bit
A/D conversion time10mS10mS10mS
Real Time ClockYesYesYes
I/F OperatorYes
I/F RS232 Ports222
I/F RS232 Baud rates300 to 115200 bps300 to 115200 bps300 to 115200 bps
I/F RS232 Data Bit7, 87, 87, 8
I/F RS232 Bit stop1, 21, 21, 2
I/F RS232 ParityNone, Odd, EvenNone, Odd, EvenNone, Odd, Even
I/F RS422/485 Ports11
I/F RS422/485 Baud rates300 to 115200 bps300 to 115200 bps
I/F RS422/485 Data bits7, 87, 8
I/F RS422/485 Bit stop1, 21, 2
I/F RS422/485 ParityNone, Odd, EvenNone, Odd, Even
I/F 1-WireSerial adapterSerial adapterSerial adapter
Ethernet I/F111
ConfigurationWeb page, Telnet, Windows utilityWeb page, Telnet, Windows utilityWeb page, Telnet, Windows utility
ProgrammingLogicLab (Free)LogicLab (Free)LogicLab (Free)
License LogicLabIncludingIncludingIncluding
Supported languagesAccording to IEC61131-3 standard (IL, ST, LD, FBD and SFC)According to IEC61131-3 standard (IL, ST, LD, FBD and SFC)According to IEC61131-3 standard (IL, ST, LD, FBD and SFC)
Firmware UpgradeRS232RS232RS232
Supported protocolsModbus RTU/ASCII, DMXModbus RTU/ASCII, DMXModbus RTU/ASCII, DMX
MountingDIN barDIN barDIN bar
ContainerPlasticPlasticPlastic
Storage temperatureFrom -40°C to +80°CFrom -40°C to +80°CFrom -40°C to +80°C
Operating temperatureFrom -20°C to +70°CFrom -20°C to +70°CFrom -20°C to +70°C
Relative humidityMax. 90%.Max. 90%.Max. 90%.
Dimensions160x90x58mm160x90x58mm160x90x58mm
Weight150g150g150g
ApprovalsCE, RoHSCE, RoHSCE, RoHS
Code (SKU) Description Price List (Discount) Net Stock Comparison
NETLOG III Full RS485 ETH Relay + Display Option 439,00 (-20%) 351,20 Net VAT excluded

1 in stock, 1 available

Compare
NETLOG III Full RS485 ETH relays 359,00 (-20%) 287,20 Net VAT excluded

1 in stock, 1 available

Compare
NETLOG III Base ETH relay 309,00 (-20%) 247,20 Net VAT excluded

5 in stock, 5 available

Compare
Code (SKU) Description Price List (Discount) Net Stock Comparison
I2C extension cable (20cm) (NOT through cable) 8,50 (-20%) 6,80 Net VAT excluded

2 in stock, 2 available

20I/O Series Expansion Module Netsyst 165,00 (-20%) 132,00 Net VAT excluded

5 in stock, 5 available

Compare
MDR-20-24 24Vdc 24W Power Supply 15,00 (-20%) 12,00 Net VAT excluded

16 in stock, 14 available

Code (SKU) Description Price List (Discount) Net Stock Comparison
Unshielded RJ45 8/8 extension cable (2m) 7,50 (-20%) 6,00 Net VAT excluded

12 in stock, 12 available

Ethernet cable UTP Cross in Copper CAT. 6 Green/Grey SF/UTP 2mt 5,00 (-20%) 4,00 Net VAT excluded

5 in stock, 5 available

I/O Simulator 200,00 (-20%) 160,00 Net VAT excluded

0 in stock, 0 available

# Title Link
0 A REST application in practice
1 How to use the spy console
2 Telnet connection to Ubiquiti devices
3 ARM7 CPU Module Upgrade
4 IP to be used in the private network
5 Configure network and IP address on Windows
6 How to protect a programme (SlimLine/Netsyst)
7 Customise system graphics Netsyst
# Code Type Description Last update Download
1 PDF Data sheet LogicLab (English) 27/10/2011
# Code Type Description Last update Download
1 MNL169C000 PDF Quick Start Guide LogicLab CPU SlimLine and Netlog III (English) 17/02/2015
2 MNL168C100 Hardware Reference Manual Netlog III 11/07/2014
3 MNL151D120 PDF IEC61131-3 Programming Manual (English) 06/02/2023
4 MNL151D040 PDF IEC61131-3 Programming Manual (English) 06/02/2023
5 PDF Quick start guide for LogicLab 30/06/2010
# Code Type Description Last update Download
1 ANT007A000 Correct use of relay output modules 22/11/2010
2 ANT005A*00 Correct wiring of RS485 networks 07/09/2004
# Code Type Description Last update Download
1 Mechanical dimensions of line products Netsyst (DXF format) 06/12/2006
# Code Type Description Last update Download
1 FRM124C*00 RoHS Declaration of Conformity SlimLine/Netsyst 30/07/2019
# Code Type Description Last update Download
1 PTP179A000 Example of using functions and FB library "eLLabMathsLib". 11/09/2020
2 PTP178A000 Programmes example video tutorials "Using SlimLine" 20/07/2020
3 PTP176B000 Example of using functions and FB library "eLLabI2CDevsLib". 02/09/2020
4 PTP167A100 Alias "BeebotteStartUp", example connection to Beebotte service 28/12/2020
5 PTP158A000 Alias "BeebotteMQTT", posting topic on Beebotte 15/03/2019
6 PTP157A000 Alias "HTTPServerDemo", FB HTTPServer demo 12/03/2019
7 PTP156B400 eLLabHTTPLib library examples 10/05/2022
8 PTP155A000 Alias "ScopeMeter", oscilloscope demonstration with web page 08/02/2019
9 PTP153B500 Dynamic web pages for systems SlimLine/Netsyst 03/10/2023
10 PTP151A000 Alias "CmdLineIFServer" command line server 09/11/2018
11 PTP148A000 Examples of use, Integrated HMI Library (eLLabHMIBuiltInLib_xxxx) 27/12/2017
12 PTP142A000 Responsive dashboard example project in Ajax 10/06/2016
13 PTP141C110 Examples of use, Modbus device library (eLLabMdbDevsLib) 02/09/2020
14 PTP140A000 Examples of use, Device Management Library (eLabDevicesLib_xxxx) 18/04/2006
15 PTP137B200 Examples of use, SNMP protocol library (eLLabSNMPLib) 15/12/2020
16 PTP136B000 Examples of use, Data Logging Library (eLLabLogLib) 29/07/2020
17 PTP135B330 Alias "RESTSvcDemo", demonstration connection to the REST service portal 02/01/2019
18 PTP126A000 Examples of use, HWgroup Device Library (eHwGSpLib_xxxx) 14/03/2012
19 PTP123C000 Examples of use, NMEA protocol library (eLLabNMEALib_xxxx) 15/06/2020
20 PTP120B200 Examples of use, one-wire library (ePLC1WireLib) 22/02/2022
21 PTP118B400 Usage examples, utility library (eLLabModemLib_xxx) 01/08/2018
22 PTP117A100 Examples of use, DMX library (eDMXLib) 07/09/2010
23 PTP116C130 Example of using functions and FB library "eLLabXUnified12Lib". 16/12/2020
24 PTP115C100 Usage examples, IEC61131-3 standard library (eLLabStdLib) 05/08/2021
25 PTP114B520 Usage examples, utility library (eLLabUtyLib) 14/06/2022
26 MDP126A100 Alias "ESPurnaSonoff", Sonoff device management with ESPurna firmware v1.1.0 05/12/2018
# Code Type Description Last update Download
1 SFW186A400 Firmware Netsyst 20 I/O mixed signal (PCB part number 099*) v1.4.0 27/11/2017
# Code Type Description Last update Download
1 PCK033I130 IEC61131-3 suite installation package (LogicLab Ver. 5.22.0.24) v9.1.30 10/05/2023
# Code Type Description Last update Download
1 PCS101A000 Dimensional keyboard products line Netsyst 07/09/2004
# Title Link
0 Program update without providing source files
1 Acquire serial port CTS signal status
2 Calculation of the number of possible extension modules
3 I/O exchange between two Netlog with radiomodem
4 The new version of Netlog (Version III) has been launched.

1 review for Netlog III - Programmable controllers

  1. Luigi Barrotta (proprietario verificato)

    I have been using Netlog since the first version 17 years ago. It is a very good product available with software function blocks for a wide variety of uses.
    Excellent customer support completes the supply. W la made in italy

Only customers who have logged in and purchased this product can leave a review.